{"product_id":"natural-gas-automotive-paint-booth-na-g10-full-size-car-spray-booth","title":"NA-G10 Natural Gas Automotive Paint Booth – Full-Size Car Spray Booth | CE, FCC certified","description":"\u003cdiv class=\"product-description na-g10\"\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eNA-G10 Natural Gas Automotive Spray Paint Booth\u003c\/strong\u003e is a full-size downdraft car spray booth for collision repair,\n    refinish and custom shops that want cleaner finishes and predictable cycle time – with a traditional burner-style heating system\n    instead of electric infrared.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    It is designed for body shops worldwide, with a primary focus on the needs and workflows of North American (especially US)\n    collision centers. Local installers and engineers can adapt power, burner configuration and compliance to your country or region.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Note: This booth model is continuously improved. Final specs, components and drawings may differ slightly from the\n    information shown here. Always follow your official quotation and installation documents as the source of truth.\n  \u003c\/p\u003e\n\n  \u003c!-- FULL SPEC TABLE – NA-G10 --\u003e\n  \u003ch3 class=\"spec-title\"\u003eNA-G10 Natural Gas Automotive Spray Paint Booth – Full Specifications\u003c\/h3\u003e\n\n  \u003ctable class=\"spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003c!-- MODEL \u0026 SIZE --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eModel \u0026amp; Size\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eModel name\u003c\/td\u003e\n        \u003ctd\u003eNA-G10 Natural Gas Automotive Spray Paint Booth\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOutside size (L × W × H)\u003c\/td\u003e\n        \u003ctd\u003e7000 × 5100 × 3300 mm (approx. 23.0' × 16.7' × 10.8')\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eInside working size (L × W × H)\u003c\/td\u003e\n        \u003ctd\u003e6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7')\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- DOORS \u0026 ACCESS --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eDoors \u0026amp; Access\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMain entrance door\u003c\/td\u003e\n        \u003ctd\u003e3000 × 2600 mm (W × H), bordered wall-panel doors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWork \/ personnel door\u003c\/td\u003e\n        \u003ctd\u003e750 × 1900 mm (W × H), same color as wall panels\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- HOUSING SYSTEM --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eHousing System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eTop plenum height\u003c\/td\u003e\n        \u003ctd\u003eApprox. 370 mm purification \/ airflow layer above the cabin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWall panels\u003c\/td\u003e\n        \u003ctd\u003e50 mm socket-type flame-retardant EPS insulation board with 0.32 mm color steel plate\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eRoof (top plate)\u003c\/td\u003e\n        \u003ctd\u003e0.8 mm galvanized bent steel plate\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBottom structure\u003c\/td\u003e\n        \u003ctd\u003e2 floor grilles + 3 patterned steel plates; climbing platform approx. 750 × 1800 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBase\u003c\/td\u003e\n        \u003ctd\u003e280 mm high galvanized steel base, sheet thickness about 1.0 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- AIR INTAKE \u0026 EXHAUST --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eAir Intake \u0026amp; Exhaust System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eVentilation pattern\u003c\/td\u003e\n        \u003ctd\u003eAir supplied from above and exhausted downward through floor grilles (downdraft)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eInlet fan\u003c\/td\u003e\n        \u003ctd\u003e2 × 3 kW dual fans (supply)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOutlet fan\u003c\/td\u003e\n        \u003ctd\u003eNot included in the base NA-G10 configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eDuctwork\u003c\/td\u003e\n        \u003ctd\u003e2 rectangular air ducts, 1 × 90° elbow and 1 × 45° elbow\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eEquipment \/ air box position\u003c\/td\u003e\n        \u003ctd\u003eCan be installed on the right, left or rear side of the booth\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- HEATING --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eHeating \u0026amp; Baking\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eHeating method\u003c\/td\u003e\n        \u003ctd\u003eNatural-gas burner heating (no on-booth diesel system)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBurner and heating capacity\u003c\/td\u003e\n        \u003ctd\u003eFS10-type natural gas burner, approx. 100,000 kcal\/h reference capacity\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- LIGHTING --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eLighting System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOverhead lighting\u003c\/td\u003e\n        \u003ctd\u003e8 sets of 4 × 16 W LED high-efficiency energy-saving lamps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSide lighting\u003c\/td\u003e\n        \u003ctd\u003eNone (overhead lighting only)\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- FILTRATION \u0026 CONTROL --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eFiltration \u0026amp; Controls\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eFiltration system\u003c\/td\u003e\n        \u003ctd\u003eTop filtration, vent filtration and bottom filtration (multi-stage chain)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eElectric control system\u003c\/td\u003e\n        \u003ctd\u003eIntelligent electronic control system with knob interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- POWER --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eTotal installed electrical power\u003c\/td\u003e\n        \u003ctd\u003eApprox. 6.5 kW (fans, controls and auxiliaries – burner uses natural gas fuel)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- STYLING FOR TABLE + DROPDOWNS --\u003e\n  \u003cstyle\u003e\n    .na-g10 .spec-title {\n      margin-top: 2rem;\n      font-size: 1.2rem;\n      font-weight: 600;\n    }\n    .na-g10 .spec-table {\n      width: 100%;\n      border-collapse: collapse;\n      margin: 0 0 2rem;\n      font-size: 0.95rem;\n    }\n    .na-g10 .spec-table th,\n    .na-g10 .spec-table td {\n      border: 1px solid #e2e2e2;\n      padding: 8px 10px;\n      vertical-align: top;\n    }\n    .na-g10 .spec-table .spec-group th {\n      background: #f4f4f4;\n      text-transform: uppercase;\n      letter-spacing: 0.03em;\n      font-size: 0.82rem;\n    }\n    .na-g10 .spec-table tr:nth-child(odd):not(.spec-group) {\n      background: #fcfcfc;\n    }\n\n    .na-g10 .accordion-intro {\n      margin: 1rem 0 0.5rem;\n      font-weight: 600;\n      font-size: 0.98rem;\n    }\n\n    .na-g10 details {\n      border: 1px solid #e2e2e2;\n      border-radius: 6px;\n      margin: 0 0 0.75rem;\n      padding: 0.45rem 0.8rem;\n      background: #fafafa;\n    }\n    .na-g10 details[open] {\n      background: #ffffff;\n      box-shadow: 0 1px 3px rgba(0,0,0,0.03);\n    }\n    .na-g10 details \u003e summary {\n      list-style: none;\n      cursor: pointer;\n      font-weight: 600;\n      display: flex;\n      align-items: center;\n      gap: 0.5rem;\n      font-size: 0.98rem;\n    }\n    .na-g10 details \u003e summary::-webkit-details-marker {\n      display: none;\n    }\n    .na-g10 details \u003e summary::before {\n      content: \"▶\";\n      font-size: 0.75rem;\n      transition: transform 0.15s ease;\n    }\n    .na-g10 details[open] \u003e summary::before {\n      transform: rotate(90deg);\n    }\n    .na-g10 details p,\n    .na-g10 details ul {\n      margin-top: 0.5rem;\n      font-size: 0.94rem;\n    }\n    .na-g10 details ul {\n      padding-left: 1.1rem;\n    }\n    .na-g10 .faq-question {\n      margin-top: 0.75rem;\n      font-weight: 600;\n      font-size: 0.96rem;\n    }\n  \u003c\/style\u003e\n\n  \u003cp class=\"accordion-intro\"\u003eClick a section below to see how these specs affect daily work in the booth.\u003c\/p\u003e\n\n  \u003c!-- ORDERED FROM MOST IMPORTANT FOR MOST BUYERS --\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eBooth size and working area\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 paint booth measures 7000 × 5100 × 3300 mm outside and 6900 × 3900 × 2650 mm inside, giving enough space for\n      most sedans, coupes, hatchbacks, SUVs and light trucks while still leaving room to move around the vehicle.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eOutside size: 7000 × 5100 × 3300 mm (approx. 23.0' × 16.7' × 10.8').\u003c\/li\u003e\n      \u003cli\u003eInside working size: 6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7').\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      For many buyers, this matches what they expect from a standard full-size automotive spray booth footprint.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eHeating performance and bake time\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 uses a natural-gas burner (FS10-type) as the primary heat source. With around 100,000 kcal\/h of reference\n      heating capacity, it is designed to take the booth from near room temperature up to typical refinish bake temperatures\n      under factory reference conditions.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eHeating type: natural-gas burner (no on-booth diesel burner and no electric infrared package).\u003c\/li\u003e\n      \u003cli\u003eApproximate burner capacity: about 100,000 kcal\/h (factory reference, natural gas).\u003c\/li\u003e\n      \u003cli\u003eSupports forced drying of primer and clear coat with gas-fired heat.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      This suits shops that prefer traditional burner-style heating and want to keep the electrical load lower while still\n      maintaining predictable bake cycles.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eAirflow and ventilation\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 is a downdraft automotive spray booth: air comes from the plenum above and is drawn down through the floor\n      grilles to move overspray away from the painter and the vehicle.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eDowndraft pattern: air is delivered from above and pulled down through the floor grilles.\u003c\/li\u003e\n      \u003cli\u003eSupply fans: 2 × 3 kW dual fans on the intake side.\u003c\/li\u003e\n      \u003cli\u003eDuctwork: 2 straight ducts plus 90° and 45° elbows to connect into your exhaust stack or treatment system.\u003c\/li\u003e\n      \u003cli\u003eOutlet fan: not included in the base NA-G10 configuration (can be added or specified in custom setups).\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      The downdraft pattern helps keep overspray headed toward the floor instead of hanging in the painter’s line of sight.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eFiltration and finish quality\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 combines top, vent and floor filtration to help control dust and overspray in the automotive paint booth.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eTop filtration in the ceiling area above the booth.\u003c\/li\u003e\n      \u003cli\u003eVent filtration on incoming make-up air.\u003c\/li\u003e\n      \u003cli\u003eBottom filtration beneath the floor grilles.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      With regular filter maintenance, this multi-stage chain is intended to support clean refinish work and reduce rework due\n      to dirt in the clear coat.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eConstruction and access\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 cabin uses insulated steel wall panels, a galvanized roof and a raised steel base with grilles and plates to\n      feel like a permanent, professional installation.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003e50 mm EPS wall panels with 0.32 mm color-steel facing for insulation and rigidity.\u003c\/li\u003e\n      \u003cli\u003e0.8 mm galvanized roof plate.\u003c\/li\u003e\n      \u003cli\u003eApprox. 370 mm plenum \/ purification layer above the booth ceiling.\u003c\/li\u003e\n      \u003cli\u003e2 floor grilles + 3 patterned plates on a 280 mm high galvanized base, with climbing platform around 750 × 1800 mm.\u003c\/li\u003e\n      \u003cli\u003eMain door: bordered wall-panel doors, 3000 × 2600 mm.\u003c\/li\u003e\n      \u003cli\u003ePersonnel door: 750 × 1900 mm, matching the booth wall color.\u003c\/li\u003e\n      \u003cli\u003eEquipment box \/ air unit can be mounted on the right, left or rear side to suit your building.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      When inspectors, insurers or fleet customers walk into the spray area, the booth presents as a serious long-term asset\n      rather than a temporary box.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003ePower requirements and regions\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 is a gas-heated industrial spray booth designed to run on three-phase power for fans and controls, with exact\n      voltage and frequency set per order and region. Burner fuel is supplied by your natural gas service.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eTotal installed electrical power: approx. 6.5 kW (fans, controls and auxiliaries).\u003c\/li\u003e\n      \u003cli\u003eGas-fired heat from an FS10-type burner, using natural gas as the fuel.\u003c\/li\u003e\n      \u003cli\u003eDesigned for industrial three-phase power (exact voltage and frequency configured per order and region).\u003c\/li\u003e\n      \u003cli\u003e\n        For the US and other markets, local electrical and mechanical engineers adapt the booth to the available three-phase supply,\n        gas service and safety devices to meet local code.\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      Final approval always depends on local building codes, fire regulations and environmental rules in your area.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWho is this car spray booth for?\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G10 is aimed at body shop owners comparing full-size automotive spray booths for everyday collision and refinish\n      work who prefer natural-gas-fired heating.\n    \u003c\/p\u003e\n    \u003cp\u003eTypical questions from buyers include:\u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003e“What is the best full-size automotive spray booth with a gas-fired burner for my body shop?”\u003c\/li\u003e\n      \u003cli\u003e“What size paint booth do I need for cars and light trucks?”\u003c\/li\u003e\n      \u003cli\u003e“Is a natural gas automotive spray booth enough to bake clear coat fast?”\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003eTypical buyers:\u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eCollision and refinish shops that need to control cycle time and key-to-key.\u003c\/li\u003e\n      \u003cli\u003eGrowing body shops planning a 10–15 year infrastructure upgrade, not a temporary fix.\u003c\/li\u003e\n      \u003cli\u003eOwners who care about image with inspectors, insurers, DRP partners and painters.\u003c\/li\u003e\n      \u003cli\u003eShops that prefer gas heating and a clean, modern booth interior with a downdraft airflow pattern.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eFAQ – common buyer questions\u003c\/summary\u003e\n\n    \u003cp class=\"faq-question\"\u003eIs this a good automotive spray booth for a small to medium body shop?\u003c\/p\u003e\n    \u003cp\u003e\n      Yes. The NA-G10 footprint and performance are tuned for daily collision workloads on cars, SUVs and light trucks. If you\n      are searching for a “full-size automotive spray paint booth with a natural gas burner for collision repair”, this model fits that use case.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eDoes this booth work with waterborne paint systems?\u003c\/p\u003e\n    \u003cp\u003e\n      Yes. Airflow, heating and filtration are suitable for modern solvent-borne and waterborne refinish systems when installed\n      and operated according to your paint manufacturer’s guidelines.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eCan I install this car spray booth in the United States or other countries?\u003c\/p\u003e\n    \u003cp\u003e\n      The booth is designed to be adaptable to different power systems, gas services and regulations, including US and other markets.\n      Final approval always depends on local building departments, fire marshals and environmental agencies in your region.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eAre the specifications fixed?\u003c\/p\u003e\n    \u003cp\u003e\n      No. The NA-G10 platform is continuously updated. Dimensions, components and configuration may change over time or be\n      customized. Always rely on your signed drawings, quotation and installation package for exact, current specs.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Disclaimer: All data on this page is provided as a general reference for buyers comparing automotive spray booths.\n      Specifications, power configuration, components and images may be updated or customized without prior notice.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n","brand":"Nord Auto Engineering","offers":[{"title":"Default Title","offer_id":53434704953674,"sku":null,"price":17990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0982\/1595\/2714\/files\/2_png_a3f818e7-b674-40e2-9a7b-915fe664db5e.png?v=1763971636","url":"https:\/\/nordautoshop.com\/products\/natural-gas-automotive-paint-booth-na-g10-full-size-car-spray-booth","provider":"Nord Auto Shop","version":"1.0","type":"link"}