{"product_id":"natural-gas-automotive-paint-booth-na-g30-full-size-car-spray-booth","title":"NA-G30 Natural Gas Automotive Paint Booth – Full-Size Car Spray Booth | CE, FCC certified","description":"\u003cdiv class=\"product-description na-g30\"\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eNA-G30 Natural Gas Automotive Spray Paint Booth\u003c\/strong\u003e is a larger full-size downdraft car spray booth for collision repair,\n    refinish and custom shops that want stronger airflow, more lighting and predictable bake times – with a high-capacity natural-gas\n    burner and both supply and exhaust fans included in the base configuration.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    It is designed for body shops worldwide, with a primary focus on the needs and workflows of North American (especially US)\n    collision centers. Local installers and engineers can adapt power, gas trains and compliance to your country or region.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Note: This booth model is continuously improved. Final specs, components and drawings may differ slightly from the\n    information shown here. Always follow your official quotation and installation documents as the source of truth.\n  \u003c\/p\u003e\n\n  \u003c!-- FULL SPEC TABLE – NA-G30 --\u003e\n  \u003ch3 class=\"spec-title\"\u003eNA-G30 Natural Gas Automotive Spray Paint Booth – Full Specifications\u003c\/h3\u003e\n\n  \u003ctable class=\"spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003c!-- MODEL \u0026 SIZE --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eModel \u0026amp; Size\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eModel name\u003c\/td\u003e\n        \u003ctd\u003eNA-G30 Natural Gas Automotive Spray Paint Booth\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOutside size (L × W × H)\u003c\/td\u003e\n        \u003ctd\u003e7000 × 5250 × 3400 mm (approx. 23.0' × 17.2' × 11.2')\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eInside working size (L × W × H)\u003c\/td\u003e\n        \u003ctd\u003e6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7')\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- DOORS \u0026 ACCESS --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eDoors \u0026amp; Access\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMain entrance door\u003c\/td\u003e\n        \u003ctd\u003e3000 × 2600 mm (W × H), sheet-metal main gate with bordered wall-panel frame\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWork \/ personnel door\u003c\/td\u003e\n        \u003ctd\u003e750 × 1900 mm (W × H), personnel door with customizable colors\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- HOUSING SYSTEM --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eHousing System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eTop plenum height\u003c\/td\u003e\n        \u003ctd\u003eApprox. 450 mm purification \/ airflow layer above the cabin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWall panels\u003c\/td\u003e\n        \u003ctd\u003e50 mm socket-type flame-retardant EPS insulation board with 0.42 mm color steel plate\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eRoof (top plate)\u003c\/td\u003e\n        \u003ctd\u003e1.0 mm galvanized bent steel plate\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBottom structure\u003c\/td\u003e\n        \u003ctd\u003e3 floor grilles + 2 patterned plates, or optional full-grille floor configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBase\u003c\/td\u003e\n        \u003ctd\u003e300 mm high galvanized steel base, sheet thickness about 1.0 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- AIR INTAKE \u0026 EXHAUST --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eAir Intake \u0026amp; Exhaust System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eVentilation pattern\u003c\/td\u003e\n        \u003ctd\u003eAir supplied from above and exhausted downward through floor grilles (downdraft)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eInlet fan\u003c\/td\u003e\n        \u003ctd\u003e2 × 4 kW dual fans (supply)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOutlet fan\u003c\/td\u003e\n        \u003ctd\u003e1 × 7.5 kW centrifugal exhaust fan (included in base configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eDuctwork\u003c\/td\u003e\n        \u003ctd\u003e4 rectangular air ducts, 1 × 90° elbow and 1 × 45° elbow\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eEquipment \/ air box position\u003c\/td\u003e\n        \u003ctd\u003eCan be installed on the right, left or rear side of the booth\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- HEATING --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eHeating \u0026amp; Baking\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eHeating method\u003c\/td\u003e\n        \u003ctd\u003eNatural-gas burner heating (no on-booth diesel system)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eBurner and heating capacity\u003c\/td\u003e\n        \u003ctd\u003eFS20-type natural gas burner, approx. 180,000 kcal\/h reference capacity\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- LIGHTING --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eLighting System\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOverhead lighting\u003c\/td\u003e\n        \u003ctd\u003e8 sets of 4 × 18 W LED high-efficiency energy-saving lamps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSide lighting\u003c\/td\u003e\n        \u003ctd\u003e10 sets of 1 × 60 W LED high-efficiency energy-saving lamps\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- FILTRATION \u0026 CONTROL --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003eFiltration \u0026amp; Controls\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eFiltration system\u003c\/td\u003e\n        \u003ctd\u003eTop filtration, vent filtration, bottom filtration and activated carbon filter cotton\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eElectric control system\u003c\/td\u003e\n        \u003ctd\u003eIntelligent electronic control system with knob interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003c!-- POWER --\u003e\n      \u003ctr class=\"spec-group\"\u003e\n        \u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eTotal installed electrical power\u003c\/td\u003e\n        \u003ctd\u003eApprox. 16.7 kW (fans, controls and auxiliaries – burner uses natural gas fuel)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- STYLING FOR TABLE + DROPDOWNS --\u003e\n  \u003cstyle\u003e\n    .na-g30 .spec-title {\n      margin-top: 2rem;\n      font-size: 1.2rem;\n      font-weight: 600;\n    }\n    .na-g30 .spec-table {\n      width: 100%;\n      border-collapse: collapse;\n      margin: 0 0 2rem;\n      font-size: 0.95rem;\n    }\n    .na-g30 .spec-table th,\n    .na-g30 .spec-table td {\n      border: 1px solid #e2e2e2;\n      padding: 8px 10px;\n      vertical-align: top;\n    }\n    .na-g30 .spec-table .spec-group th {\n      background: #f4f4f4;\n      text-transform: uppercase;\n      letter-spacing: 0.03em;\n      font-size: 0.82rem;\n    }\n    .na-g30 .spec-table tr:nth-child(odd):not(.spec-group) {\n      background: #fcfcfc;\n    }\n\n    .na-g30 .accordion-intro {\n      margin: 1rem 0 0.5rem;\n      font-weight: 600;\n      font-size: 0.98rem;\n    }\n\n    .na-g30 details {\n      border: 1px solid #e2e2e2;\n      border-radius: 6px;\n      margin: 0 0 0.75rem;\n      padding: 0.45rem 0.8rem;\n      background: #fafafa;\n    }\n    .na-g30 details[open] {\n      background: #ffffff;\n      box-shadow: 0 1px 3px rgba(0,0,0,0.03);\n    }\n    .na-g30 details \u003e summary {\n      list-style: none;\n      cursor: pointer;\n      font-weight: 600;\n      display: flex;\n      align-items: center;\n      gap: 0.5rem;\n      font-size: 0.98rem;\n    }\n    .na-g30 details \u003e summary::-webkit-details-marker {\n      display: none;\n    }\n    .na-g30 details \u003e summary::before {\n      content: \"▶\";\n      font-size: 0.75rem;\n      transition: transform 0.15s ease;\n    }\n    .na-g30 details[open] \u003e summary::before {\n      transform: rotate(90deg);\n    }\n    .na-g30 details p,\n    .na-g30 details ul {\n      margin-top: 0.5rem;\n      font-size: 0.94rem;\n    }\n    .na-g30 details ul {\n      padding-left: 1.1rem;\n    }\n    .na-g30 .faq-question {\n      margin-top: 0.75rem;\n      font-weight: 600;\n      font-size: 0.96rem;\n    }\n  \u003c\/style\u003e\n\n  \u003cp class=\"accordion-intro\"\u003eClick a section below to see how these specs affect daily work in the booth.\u003c\/p\u003e\n\n  \u003c!-- ORDERED FROM MOST IMPORTANT FOR MOST BUYERS --\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eBooth size and working area\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 paint booth measures 7000 × 5250 × 3400 mm outside and 6900 × 3900 × 2650 mm inside, giving enough space for\n      most sedans, coupes, hatchbacks, SUVs and light trucks while still leaving room to move around the vehicle.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eOutside size: 7000 × 5250 × 3400 mm (approx. 23.0' × 17.2' × 11.2').\u003c\/li\u003e\n      \u003cli\u003eInside working size: 6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7').\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      Compared to many standard booths, the NA-G30 offers a bit more width and plenum height, which can help with airflow\n      uniformity and painter comfort around larger vehicles.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eHeating performance and bake time\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 uses a high-capacity natural-gas burner (FS20-type) as the primary heat source. With around 180,000 kcal\/h of\n      reference heating capacity, it is designed to bring the cabin from near room temperature up to typical refinish bake\n      temperatures quickly under factory reference conditions.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eHeating type: natural-gas burner (no on-booth diesel burner and no electric infrared package).\u003c\/li\u003e\n      \u003cli\u003eApproximate burner capacity: about 180,000 kcal\/h (factory reference, natural gas).\u003c\/li\u003e\n      \u003cli\u003eSupports forced drying of primer and clear coat with gas-fired heat for predictable cycle times.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      This suits higher-throughput shops that want stronger gas heat while keeping electrical demand focused on fans and controls.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eAirflow and ventilation\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 is a downdraft automotive spray booth: air comes from the plenum above and is drawn down through the floor\n      grilles to move overspray away from the painter and the vehicle. Larger fan sizes provide stronger airflow and pressure\n      control than entry-level booths.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eDowndraft pattern: air is delivered from above and pulled down through the floor grilles.\u003c\/li\u003e\n      \u003cli\u003eSupply fans: 2 × 4 kW dual fans on the intake side.\u003c\/li\u003e\n      \u003cli\u003eExhaust fan: 1 × 7.5 kW centrifugal exhaust fan included in the standard package.\u003c\/li\u003e\n      \u003cli\u003eDuctwork: 4 straight ducts plus 90° and 45° elbows to connect into your exhaust stack or treatment system.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      Balanced intake and exhaust capacity help maintain consistent airflow and booth pressure throughout the spray and bake\n      cycles, even with busy daily workloads.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eFiltration and finish quality\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 combines multi-stage filtration with an added activated-carbon layer to help control both dust and paint\n      odors in and around the booth.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eTop filtration in the ceiling area above the booth.\u003c\/li\u003e\n      \u003cli\u003eVent filtration on incoming make-up air.\u003c\/li\u003e\n      \u003cli\u003eBottom filtration beneath the floor grilles.\u003c\/li\u003e\n      \u003cli\u003eActivated carbon filter cotton for additional odor control and fine overspray capture.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      With regular filter maintenance, this chain is intended to support clean refinish work and reduce rework due to dirt\n      or contamination in the clear coat.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eConstruction and access\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 cabin uses heavier-gauge insulated wall panels, a thicker galvanized roof and a raised steel base with\n      configurable floor grilles to feel like a long-term, professional installation.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003e50 mm EPS wall panels with 0.42 mm color-steel facing for added rigidity.\u003c\/li\u003e\n      \u003cli\u003e1.0 mm galvanized roof plate for increased durability.\u003c\/li\u003e\n      \u003cli\u003eApprox. 450 mm plenum \/ purification layer above the booth ceiling for improved airflow distribution.\u003c\/li\u003e\n      \u003cli\u003eFloor options: 3 grilles + 2 patterned plates or full-grille floor, on a 300 mm high galvanized base.\u003c\/li\u003e\n      \u003cli\u003eMain sheet-metal gate: 3000 × 2600 mm with bordered panel frame.\u003c\/li\u003e\n      \u003cli\u003ePersonnel door: 750 × 1900 mm with customizable color to match your shop image.\u003c\/li\u003e\n      \u003cli\u003eEquipment box \/ air unit can be mounted on the right, left or rear side to suit your building layout.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      The overall look and feel help reassure inspectors, insurers and fleet customers that you’re operating a modern,\n      professionally equipped spray environment.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003ePower requirements and regions\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 is a gas-heated industrial spray booth designed to run on three-phase power for fans and controls, with exact\n      voltage and frequency set per order and region. Burner fuel is supplied by your natural gas service.\n    \u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eTotal installed electrical power: approx. 16.7 kW (fans, controls and auxiliaries).\u003c\/li\u003e\n      \u003cli\u003eGas-fired heat from an FS20-type burner, using natural gas as the fuel.\u003c\/li\u003e\n      \u003cli\u003eDesigned for industrial three-phase power (exact voltage and frequency configured per order and region).\u003c\/li\u003e\n      \u003cli\u003e\n        In most markets, local electrical and mechanical engineers adapt the booth to the available three-phase supply,\n        gas service and safety devices to meet local code.\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\n      Final approval always depends on local building codes, fire regulations and environmental rules in your area.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWho is this car spray booth for?\u003c\/summary\u003e\n    \u003cp\u003e\n      The NA-G30 is aimed at body shop owners comparing larger full-size automotive spray booths for everyday collision and\n      refinish work, with higher airflow and heating capacity than basic models.\n    \u003c\/p\u003e\n    \u003cp\u003eTypical questions from buyers include:\u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003e“Do I need a larger natural-gas-fired booth for my collision center?”\u003c\/li\u003e\n      \u003cli\u003e“Will extra lighting and stronger airflow help reduce rework in my shop?”\u003c\/li\u003e\n      \u003cli\u003e“What size booth is best if I’m planning for more volume in the next 10–15 years?”\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003eTypical buyers:\u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eCollision and refinish shops with growing throughput and demanding cycle-time targets.\u003c\/li\u003e\n      \u003cli\u003eShops upgrading from an older or smaller booth to support OEM certification or DRP expectations.\u003c\/li\u003e\n      \u003cli\u003eOwners who care about image with inspectors, insurers, DRP partners and painters.\u003c\/li\u003e\n      \u003cli\u003eOperations that prefer gas heating, strong downdraft airflow and integrated exhaust in the base package.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eFAQ – common buyer questions\u003c\/summary\u003e\n\n    \u003cp class=\"faq-question\"\u003eIs this a good automotive spray booth for a busy collision center?\u003c\/p\u003e\n    \u003cp\u003e\n      Yes. The NA-G30 footprint, stronger fans and higher burner capacity are tuned for daily collision workloads on cars, SUVs\n      and light trucks where consistent cycle time is critical.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eDoes this booth work with waterborne paint systems?\u003c\/p\u003e\n    \u003cp\u003e\n      Yes. Airflow, heating and filtration are suitable for modern solvent-borne and waterborne refinish systems when installed\n      and operated according to your paint manufacturer’s guidelines.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eCan I install this car spray booth in the United States or other countries?\u003c\/p\u003e\n    \u003cp\u003e\n      The booth is designed to be adaptable to different power systems, gas services and regulations, including US and other markets.\n      Final approval always depends on local building departments, fire marshals and environmental agencies in your region.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq-question\"\u003eAre the specifications fixed?\u003c\/p\u003e\n    \u003cp\u003e\n      No. The NA-G30 platform is continuously updated. Dimensions, components and configuration may change over time or be\n      customized. Always rely on your signed drawings, quotation and installation package for exact, current specs.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Disclaimer: All data on this page is provided as a general reference for buyers comparing automotive spray booths.\n      Specifications, power configuration, components and images may be updated or customized without prior notice.\n    \u003c\/p\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n","brand":"Nord Auto Engineering","offers":[{"title":"Default Title","offer_id":53434757972298,"sku":null,"price":24990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0982\/1595\/2714\/files\/2_png.png?v=1763975077","url":"https:\/\/nordautoshop.com\/products\/natural-gas-automotive-paint-booth-na-g30-full-size-car-spray-booth","provider":"Nord Auto Shop","version":"1.0","type":"link"}