Skip to product information
NA-G30 Natural Gas Automotive Paint Booth – Full-Size Car Spray Booth | CE, FCC certified
Nord Auto Engineering
In stock / made to order

NA-G30 Natural Gas Automotive Paint Booth – Full-Size Car Spray Booth | CE, FCC certified

Airflow High-volume airflow
Lighting Powerful lighting for colour match

NA-G30 Natural Gas Automotive Paint Booth – Full-Size Car Spray Booth | CE, FCC certified

Sale price  $24,990.00 Regular price  $29,990.00
Delivered – freight & duties included

Description

The NA-G30 Natural Gas Automotive Spray Paint Booth is a larger full-size downdraft car spray booth for collision repair, refinish and custom shops that want stronger airflow, more lighting and predictable bake times – with a high-capacity natural-gas burner and both supply and exhaust fans included in the base configuration.

It is designed for body shops worldwide, with a primary focus on the needs and workflows of North American (especially US) collision centers. Local installers and engineers can adapt power, gas trains and compliance to your country or region.

Note: This booth model is continuously improved. Final specs, components and drawings may differ slightly from the information shown here. Always follow your official quotation and installation documents as the source of truth.

NA-G30 Natural Gas Automotive Spray Paint Booth – Full Specifications

Model & Size
Model name NA-G30 Natural Gas Automotive Spray Paint Booth
Outside size (L × W × H) 7000 × 5250 × 3400 mm (approx. 23.0' × 17.2' × 11.2')
Inside working size (L × W × H) 6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7')
Doors & Access
Main entrance door 3000 × 2600 mm (W × H), sheet-metal main gate with bordered wall-panel frame
Work / personnel door 750 × 1900 mm (W × H), personnel door with customizable colors
Housing System
Top plenum height Approx. 450 mm purification / airflow layer above the cabin
Wall panels 50 mm socket-type flame-retardant EPS insulation board with 0.42 mm color steel plate
Roof (top plate) 1.0 mm galvanized bent steel plate
Bottom structure 3 floor grilles + 2 patterned plates, or optional full-grille floor configuration
Base 300 mm high galvanized steel base, sheet thickness about 1.0 mm
Air Intake & Exhaust System
Ventilation pattern Air supplied from above and exhausted downward through floor grilles (downdraft)
Inlet fan 2 × 4 kW dual fans (supply)
Outlet fan 1 × 7.5 kW centrifugal exhaust fan (included in base configuration)
Ductwork 4 rectangular air ducts, 1 × 90° elbow and 1 × 45° elbow
Equipment / air box position Can be installed on the right, left or rear side of the booth
Heating & Baking
Heating method Natural-gas burner heating (no on-booth diesel system)
Burner and heating capacity FS20-type natural gas burner, approx. 180,000 kcal/h reference capacity
Lighting System
Overhead lighting 8 sets of 4 × 18 W LED high-efficiency energy-saving lamps
Side lighting 10 sets of 1 × 60 W LED high-efficiency energy-saving lamps
Filtration & Controls
Filtration system Top filtration, vent filtration, bottom filtration and activated carbon filter cotton
Electric control system Intelligent electronic control system with knob interface
Power
Total installed electrical power Approx. 16.7 kW (fans, controls and auxiliaries – burner uses natural gas fuel)

Click a section below to see how these specs affect daily work in the booth.

Booth size and working area

The NA-G30 paint booth measures 7000 × 5250 × 3400 mm outside and 6900 × 3900 × 2650 mm inside, giving enough space for most sedans, coupes, hatchbacks, SUVs and light trucks while still leaving room to move around the vehicle.

  • Outside size: 7000 × 5250 × 3400 mm (approx. 23.0' × 17.2' × 11.2').
  • Inside working size: 6900 × 3900 × 2650 mm (approx. 22.6' × 12.8' × 8.7').

Compared to many standard booths, the NA-G30 offers a bit more width and plenum height, which can help with airflow uniformity and painter comfort around larger vehicles.

Heating performance and bake time

The NA-G30 uses a high-capacity natural-gas burner (FS20-type) as the primary heat source. With around 180,000 kcal/h of reference heating capacity, it is designed to bring the cabin from near room temperature up to typical refinish bake temperatures quickly under factory reference conditions.

  • Heating type: natural-gas burner (no on-booth diesel burner and no electric infrared package).
  • Approximate burner capacity: about 180,000 kcal/h (factory reference, natural gas).
  • Supports forced drying of primer and clear coat with gas-fired heat for predictable cycle times.

This suits higher-throughput shops that want stronger gas heat while keeping electrical demand focused on fans and controls.

Airflow and ventilation

The NA-G30 is a downdraft automotive spray booth: air comes from the plenum above and is drawn down through the floor grilles to move overspray away from the painter and the vehicle. Larger fan sizes provide stronger airflow and pressure control than entry-level booths.

  • Downdraft pattern: air is delivered from above and pulled down through the floor grilles.
  • Supply fans: 2 × 4 kW dual fans on the intake side.
  • Exhaust fan: 1 × 7.5 kW centrifugal exhaust fan included in the standard package.
  • Ductwork: 4 straight ducts plus 90° and 45° elbows to connect into your exhaust stack or treatment system.

Balanced intake and exhaust capacity help maintain consistent airflow and booth pressure throughout the spray and bake cycles, even with busy daily workloads.

Filtration and finish quality

The NA-G30 combines multi-stage filtration with an added activated-carbon layer to help control both dust and paint odors in and around the booth.

  • Top filtration in the ceiling area above the booth.
  • Vent filtration on incoming make-up air.
  • Bottom filtration beneath the floor grilles.
  • Activated carbon filter cotton for additional odor control and fine overspray capture.

With regular filter maintenance, this chain is intended to support clean refinish work and reduce rework due to dirt or contamination in the clear coat.

Construction and access

The NA-G30 cabin uses heavier-gauge insulated wall panels, a thicker galvanized roof and a raised steel base with configurable floor grilles to feel like a long-term, professional installation.

  • 50 mm EPS wall panels with 0.42 mm color-steel facing for added rigidity.
  • 1.0 mm galvanized roof plate for increased durability.
  • Approx. 450 mm plenum / purification layer above the booth ceiling for improved airflow distribution.
  • Floor options: 3 grilles + 2 patterned plates or full-grille floor, on a 300 mm high galvanized base.
  • Main sheet-metal gate: 3000 × 2600 mm with bordered panel frame.
  • Personnel door: 750 × 1900 mm with customizable color to match your shop image.
  • Equipment box / air unit can be mounted on the right, left or rear side to suit your building layout.

The overall look and feel help reassure inspectors, insurers and fleet customers that you’re operating a modern, professionally equipped spray environment.

Power requirements and regions

The NA-G30 is a gas-heated industrial spray booth designed to run on three-phase power for fans and controls, with exact voltage and frequency set per order and region. Burner fuel is supplied by your natural gas service.

  • Total installed electrical power: approx. 16.7 kW (fans, controls and auxiliaries).
  • Gas-fired heat from an FS20-type burner, using natural gas as the fuel.
  • Designed for industrial three-phase power (exact voltage and frequency configured per order and region).
  • In most markets, local electrical and mechanical engineers adapt the booth to the available three-phase supply, gas service and safety devices to meet local code.

Final approval always depends on local building codes, fire regulations and environmental rules in your area.

Who is this car spray booth for?

The NA-G30 is aimed at body shop owners comparing larger full-size automotive spray booths for everyday collision and refinish work, with higher airflow and heating capacity than basic models.

Typical questions from buyers include:

  • “Do I need a larger natural-gas-fired booth for my collision center?”
  • “Will extra lighting and stronger airflow help reduce rework in my shop?”
  • “What size booth is best if I’m planning for more volume in the next 10–15 years?”

Typical buyers:

  • Collision and refinish shops with growing throughput and demanding cycle-time targets.
  • Shops upgrading from an older or smaller booth to support OEM certification or DRP expectations.
  • Owners who care about image with inspectors, insurers, DRP partners and painters.
  • Operations that prefer gas heating, strong downdraft airflow and integrated exhaust in the base package.
FAQ – common buyer questions

Is this a good automotive spray booth for a busy collision center?

Yes. The NA-G30 footprint, stronger fans and higher burner capacity are tuned for daily collision workloads on cars, SUVs and light trucks where consistent cycle time is critical.

Does this booth work with waterborne paint systems?

Yes. Airflow, heating and filtration are suitable for modern solvent-borne and waterborne refinish systems when installed and operated according to your paint manufacturer’s guidelines.

Can I install this car spray booth in the United States or other countries?

The booth is designed to be adaptable to different power systems, gas services and regulations, including US and other markets. Final approval always depends on local building departments, fire marshals and environmental agencies in your region.

Are the specifications fixed?

No. The NA-G30 platform is continuously updated. Dimensions, components and configuration may change over time or be customized. Always rely on your signed drawings, quotation and installation package for exact, current specs.

Disclaimer: All data on this page is provided as a general reference for buyers comparing automotive spray booths. Specifications, power configuration, components and images may be updated or customized without prior notice.

You may also like